Home/Heating, Cooling & Home/Kerosene Heaters
Kerosene Heaters
Our main kerosene heaters guide is pinned first. The other 2 narrow the list to a specific need.
How to choose a kerosene heater
Kerosene heaters in this category separate on size, heater type and heat direction, and how fuel level and ignition are handled. Footprint and height describe the floor and vertical space a heater occupies, heater type and stated heat direction describe how heat leaves the unit, and fuel gauges, filler caps and ignition types describe checking fuel and starting the burner.
Footprint, height and weight
Footprint is the length and width a heater occupies on the floor, height is its vertical dimension, and weight is its carrying weight where a weight figure is stated. Inch figures include 12 x 11 inches on the AYDFUORT, stated as L 30cm (12 in) x W 27cm (11in) x H 47cm (19 in), 13 x 13 inches on the LBFYZBF, stated as 13"D x 13"W x 18.5"H, and 15.3 x 21.2 inches on the OVLRIJP. Heights in inches run from 18.5 inches on the LBFYZBF to 19 inches on the AYDFUORT. Centimeter figures include 33x33x46cm on the vnekjse and 47cm in the AYDFUORT size. The AYDFUORT states a net weight of 3.5 kg and a weight of 7.7 LBS, with a carrying handle.
Heater type and heat direction
Heater type is the classification given for each product, and heat direction is the direction given for heat leaving the unit. Type labels in this category run from portable on the Sengoku HeatMate, Garvee and OVLRIJP heaters to stove on the vnekjse and radiant on the LBFYZBF. Heat direction is 360° on the vnekjse, Garvee 20000, Garvee 9000, LBFYZBF and AYDFUORT heaters. The vnekjse and AYDFUORT heat in all directions at 360°, the Garvee heaters have 360° surround heat, and the LBFYZBF has 360° radiant heat distribution. A 360° figure describes heat leaving around the unit, while the type label describes the heater format.
Fuel gauge and ignition
A fuel gauge shows the remaining fuel level, a sealed fuel filler cap closes the fuel filler, and ignition type describes how the burner is started. Fuel gauges appear on the vnekjse, Garvee 20000, OVLRIJP, Garvee 9000, LBFYZBF and AHUAWA 9 heaters, and sealed fuel filler caps appear on the vnekjse, OVLRIJP and LBFYZBF heaters. Ignition runs from batteries included on the Sengoku HeatMate HMC-23K, with automatic ignition, to AA batteries not included on the Garvee 9800, with an electronic ignition system. Check whether a fuel gauge is present, and whether ignition batteries are included or not included.


